Price:To be discussed
Product introduction:Landing Gear Dedicated MPI Equipment, MPI Equipment for Landing Gear, MPI Equipment, Landing Gear
Technical Parameters:
Circumferential magnetization current output: 3P full-wave rectified current: 0~10000A, mean value, continuously adjustable, settable;
Longitudinal coil MMF: 3P full-wave rectified current: 0~30000AT, mean value, continuously adjustable, settable;
Output rated duty cycle: no less than 25%;
Demagnetization current: Circumferential: 10000A~ 0, continuously adjustable, settable;
Longitudinal: 30000AT~ 0, continuously adjustable, settable
Demagnetization frequency: DC: 0.39Hz, 0.78Hz, 1.56Hz, 2.34Hz, 3.12Hz
Demagnetization time: 30s, 40s, 50s, 60s
Remanence: no more than 0.2mT on standard test bar
Pole plate distance: 0~3600mm
Meter precision: measurement error ≤±5%; tolerance between preset current display value and working current display value should be no more than ±10%; tolerance between working value display value and actual current should be no more than ±10%;
The coil is square and internal surface side length is 750mm; central magnetic field (5 turns): ≥450GS
Input voltage: 3P4W: 380V ±5%; 50Hz
Power: 240KW
External size: body: 5200mm (L) × 800mm (H) (working surface) × 1100mm(W)
Height between guide rails and ground: 800mm; height of body outer edge: 900mm;
Max. distance between pole plates: more than 3600mm;
Power cabinet: 1100mm × 800mm × 1800mm